null

Note: Existing keyless remotes will be erased with this procedure.
          Existing working remotes will have to reprogrammed also.

1. Locate the programming connector wire located in the RH trunk area.
    You may have to pull back right side trunk trim on trunk wall to locate
    the single black/white wire.

2. The programming connector wire should have one termial in the plastic
    connector on end of black/white wire. Ground the terminal in the connector
    to  a nearby bolt or trunk latch.
    Leave connector wire connected to ground through out procedure.

3. System will now lock and unlock doors automatically to indicate
    programming mode has been activated.

4. Press any button on keyless remote. System will respond by locking
    and unlocking doors one time to indicate successful programming.

5. Repeat step 4 for to program any additonal keyless remotes including
    and existing keyless remotes. Do not remove ground wire between
    programming of keyless remotes.

6. Disconnect programming connector wire from ground to exit programming
    mode.

7. Test keyless remote(s).

--